Reference test object for on site HIRF test set up verification

Abstract : In this paper we propose a simple reference test object which is to be used as a set up verification device to be tested before High Intensity Radiated Frequency (HIRF) measurement campaigns on aircraft. This reference object has been designed to take into account both EM and mechanical requirements. It therefore ensures a good level of sensitivity and reproducibility of a reference measured transfer function between the incident E-field and an internal induced current. This object has been calibrated in laboratory using a strip-line which enables to fully control the incident EM field. Finally tests in open test site conditions have been carried out in order to provide reference transfer functions.
Document type :
Conference papers
Complete list of metadatas

Cited literature [4 references]  Display  Hide  Download

https://hal-onera.archives-ouvertes.fr/hal-01071570
Contributor : Véronique Soullier <>
Submitted on : Monday, October 6, 2014 - 11:23:28 AM
Last modification on : Tuesday, March 26, 2019 - 2:28:03 PM
Long-term archiving on : Thursday, January 8, 2015 - 4:11:28 PM

File

DEMR14028.1400570583.pdf
Files produced by the author(s)

Identifiers

  • HAL Id : hal-01071570, version 1

Collections

Citation

W. Quenum, J.P. Parmantier, O. Verstraete, D. Lemaire, F. Therond. Reference test object for on site HIRF test set up verification. EMC Europe 2014, Sep 2014, GOTHEMBURG, Sweden. ⟨hal-01071570⟩