Reference test object for on site HIRF test set up verification

Abstract : In this paper we propose a simple reference test object which is to be used as a set up verification device to be tested before High Intensity Radiated Frequency (HIRF) measurement campaigns on aircraft. This reference object has been designed to take into account both EM and mechanical requirements. It therefore ensures a good level of sensitivity and reproducibility of a reference measured transfer function between the incident E-field and an internal induced current. This object has been calibrated in laboratory using a strip-line which enables to fully control the incident EM field. Finally tests in open test site conditions have been carried out in order to provide reference transfer functions.
Type de document :
Communication dans un congrès
EMC Europe 2014, Sep 2014, GOTHEMBURG, Sweden
Liste complète des métadonnées

Littérature citée [4 références]  Voir  Masquer  Télécharger

https://hal-onera.archives-ouvertes.fr/hal-01071570
Contributeur : Véronique Soullier <>
Soumis le : lundi 6 octobre 2014 - 11:23:28
Dernière modification le : mercredi 28 mars 2018 - 14:16:10
Document(s) archivé(s) le : jeudi 8 janvier 2015 - 16:11:28

Fichier

DEMR14028.1400570583.pdf
Fichiers produits par l'(les) auteur(s)

Identifiants

  • HAL Id : hal-01071570, version 1

Collections

Citation

W. Quenum, J.P. Parmantier, O. Verstraete, D. Lemaire, F. Therond. Reference test object for on site HIRF test set up verification. EMC Europe 2014, Sep 2014, GOTHEMBURG, Sweden. 〈hal-01071570〉