Analysis of high pressure tests on wet gas flow metering with a venturi meter - ONERA - Office national d'études et de recherches aérospatiales Accéder directement au contenu
Communication Dans Un Congrès Année : 2013

Analysis of high pressure tests on wet gas flow metering with a venturi meter

P. Gajan
  • Fonction : Auteur
  • PersonId : 936347
Q. Decaudin
  • Fonction : Auteur
J.P. Couput
  • Fonction : Auteur

Résumé

This work deals with the flow metering of wet gas issued from high pressure natural reservoirs. Some recent results obtained from tests performed on the CEESI facilities are presented. They are performed at 75 bars with 0.6 beta ratio Venturi meter installed in horizontal pipe configuration. Correction factors obtained are compared to predictions deduced from the flow modelling inside of the meter. These results are analysed in order to explain the agreements or disagreement obtained between the experiments and the flow modelling.
Fichier principal
Vignette du fichier
DMAE13079.1381306112.pdf (126.03 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-01058403 , version 1 (26-08-2014)

Identifiants

  • HAL Id : hal-01058403 , version 1

Citer

P. Gajan, Q. Decaudin, J.P. Couput. Analysis of high pressure tests on wet gas flow metering with a venturi meter. The 16th International Flow Measurement Conference - (Flomeko 2013, Sep 2013, PARIS, France. ⟨hal-01058403⟩